Nortel Networks 15000 Network Router User Manual


 
Versalar 15000 Hardware Description
308684-B Rev 00
1-17
Table 1-7 describes the SSP card LEDs.
Table 1-7. SSP Card LEDs
LED State Meaning
Pwr Off Power is off.
On (green)
Power is on
.
Stat Off LED is not functioning.
On (green) SSP card is operating normally.
Flashing (green) Power-up diagnostic testing is in progress.
Diagnostic testing occurs when you cold-start the
module by cycling power, issuing the
diags
command from the BCC, or installing the SSP card
with the power on.
On (amber)
Diagnostic testing failed. The SSP card is waiting
for an automatic attempt to reinitiate diagnostic
testing. If the Stat LED lights amber again, call the
Nortel Networks Technical Solutions Center.
Run Off Processor code is not loaded.
On (green) Boot process is complete.
Flashing (green) Software initialization and loading are in progress.
On (amber) Fault is detected.
Mstr Off SSP card is not controlling the system resources.
On (green) SSP card is controlling the system resources.
Temp Off When the air temperature exceeds 65
0
C, the
system will shut down.
On (green) System temperature is normal.
On (amber) Air temperature exceeds 45
0
C.
Fan Off Fan is operating normally.
On (amber)
Fan is defective
.
Maj Off No major software alarm is detected.
On (amber) Major fault is detected, such as a component failure
or interface failure.
(continued)