21
CallPilot Mini/CallPilot 150 Installation and Maintenance Guide
Chapter 3
Preparing to install the CallPilot Mini/CallPilot 150
This chapter explains what you need before you install the CallPilot Mini/CallPilot 150.
Environment
Make sure the installation area is:
• clean, free of dust, dry and well ventilated
• between 0 and 50 degrees Celsius
• non-condensing relative humidity between 5 percent and 95 percent
• at least 4 m, or 13 ft., from any equipment that could produce electromagnetic, radio frequency
and electrostatic interference
• a wall area about 1 m (3 ft.) square
• closer than 15 m, or 50 ft., of cable length from the Norstar KSU or Meridian 1 PBX
• within 1.5 m, or about 5 ft., of a three-wire grounded electrical outlet
• a minimum of 16 cm, or 6 in., from a corner wall or other component
• a minimum of 46 cm, about 18 in., from the floor, to prevent water damage
Electrical service
Make sure the power is:
• 115/230 VAC nominal; range 100 to 240 V
• 50/60 Hz nominal; range 47 to 63 Hz
• Third-wire ground
• Unswitched
Opening the kit
Open the box and ensure that you have all the pieces, as described below:
• CallPilot Mini/CallPilot 150
• Power supply and power cord
• Wall Mount Bracket
• Four-wire, two-meter line cord
• Documentation and Client Software CD
• CallPilot Mini EMC Kit (CallPilot Mini only)
• Shielded Ethernet cable (CallPilot Mini only)