CallPilot Mini/CallPilot 150 Installation and Maintenance Guide
Chapter 3
Preparing to install the CallPilot Mini/CallPilot 150
This chapter explains what you need before you install the CallPilot Mini/CallPilot 150.
Environment
Make sure the installation area is:
clean, free of dust, dry and well ventilated
between 0 and 50 degrees Celsius
non-condensing relative humidity between 5 percent and 95 percent
at least 4 m, or 13 ft., from any equipment that could produce electromagnetic, radio frequency
and electrostatic interference
a wall area about 1 m (3 ft.) square
closer than 15 m, or 50 ft., of cable length from the Norstar KSU or Meridian 1 PBX
within 1.5 m, or about 5 ft., of a three-wire grounded electrical outlet
a minimum of 16 cm, or 6 in., from a corner wall or other component
a minimum of 46 cm, about 18 in., from the floor, to prevent water damage
Electrical service
Make sure the power is:
115/230 VAC nominal; range 100 to 240 V
50/60 Hz nominal; range 47 to 63 Hz
Third-wire ground
Unswitched
Opening the kit
Open the box and ensure that you have all the pieces, as described below:
CallPilot Mini/CallPilot 150
Power supply and power cord
Wall Mount Bracket
Four-wire, two-meter line cord
Documentation and Client Software CD
CallPilot Mini EMC Kit (CallPilot Mini only)
Shielded Ethernet cable (CallPilot Mini only)