Novatel SMART-AG Network Card User Manual


 
Technical Specifications Appendix A
SMART-AG User Manual Rev 2 51
A.2 SMART-AG Specifications
INPUT/OUTPUT CONNECTORS
SMART-AG COM/PWR
+8 to +36 V DC at 2.5 W (typical while logging)
a
For the cable pinouts and drawings, see Section A.2.1, SMART-AG
Power/Communications Development kit Cable starting on Page 53
a. When tracking GPS satellites.
Serial Com Ports RS-232 F Compliant (Rx and Tx signals only)
CAN SAE J1939/ ISO 11783/ ISO 11898 Compliant
Emulated Radar Output High= Supply Voltage -0.5V Minimum
Low= 0.5V Minimum
Load= 3K Ohm Minimum
PPS Output 3.3 V CMOS Logic Compatible
MKI Input 3.3V CMOS Logic/ 5V Tolerant
INPUT/ OUTPUT CONNECTOR PROTECTION
Electrical Conducted/
Coupled disturbance
tolerance
ISO 7637:2002 (Survives all pulse types)
LED INDICATORS
More details can also be found in Section 2.2.2, Status Indicators starting on Page 23
PHYSICAL
Size
155.3 x 66.8 x
φ155 mm
b
b. φ denotes diameter, here and in the Dimensions graphic on Page 52.
Weight 495 g maximum
ENVIRONMENTAL
Operating Temperature -40°C to +75°C
Storage Temperature -55°C to +90°C
Humidity Not to exceed 95% non-condensing
Vibration
c
c. See also the Notice section of this manual starting on Page 13.
Random MIL-STD-810F Method 514.5 C17
Sinusoidal IEC 68-2-6 ASAE EP455, 5.15.2 Level 1
Shock MIL-STD-810 F Method 516.5