Novatel SMART-AG Network Card User Manual


 
54 SMART-AG User Manual Rev 2
Appendix A Technical Specifications
Table 7: SMART-AG Cable Pinouts
A.2.2 SMART-AG Connector and Cable Requirements
Custom cables for installing your SMART-AG can be created using he following guidelines:
• Wire size: must be 0.5 mm-1.25 mm (20-16 AWG)
• Batt + connection must be protected by 5A fast blow fuse
Colour Signal Name J1 J2 J3 Label
Red COM1_TXD 1 2
White COM1_RXD 2 3
Red COM2_TXD 3 2
White COM2_RXD 4 3
Black COM1 GND 5 5
Black COM2 GND 5 5
White-Black MKI GND 5 MKI GND
White-Black ER GND 5 ER GND
White-Black PPS GND 5 PULSE PER
SECOND
GND
Yellow CANI+ 6 CANI +
Green CANI- 7 CANI -
- RESERVED 8
Black PWR RET (GND) 9 BATT -
Blue EMULATED
RADAR OUT
10 ER_OUT
White EVENT MARK IN 11 MKI
Orange PPS 12 PPS
- RESERVED 13
Red PWR INPUT 14 BATT +