The fuser is located inside the printer just behind the four image
drum units.
Switch off the printer.
1. Press the cover release and open the printer’s top cover
fully.
2. Identify the fuser handle (1) on the top of the fuser unit.
3. Pull the fuser retaining lever (2) towards the front of the
printer so that it is fully upright.
4. Holding the fuser by its handle (1), lift the fuser straight
up and out of the printer. If the fuser is still warm, place it
on a flat surface which will not be damaged by heat.
WARNING!
If the printer has recently been powered on, some
fuser components will be very hot. Handle the fuser
with extreme care, holding it only by its handle, which
will only be mildly warm to the touch. A warning label
clearly indicates the area. If in doubt, switch the
printer off and wait at least 10 minutes for the fuser
to cool before opening the printer cover.
C
M
Y
K
1
2