Olicom 8600 Switch User Manual


 
110
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641 Switch Configuration
The lowest numbered port of the CrossLink is called the primary port. CrossLink
software learns addresses differently than regular ports, as follows:
New source address.
When a packet arrives at a CrossLink port with an
unknown source address, the system module creates an entry in the master
table and the port table for the CrossLink. The system module assigns the
primary port in the CrossLink as the location of the address.
For additional source addresses, the system module assigns locations
alternately to other ports in the CrossLink. When all ports in the CrossLink
have at least one address assigned, the system module starts assigning from the
primary port again.
New destination address.
An unknown destination address packet is sent out
on the primary ports of the CrossLink, but entries are not made in ports tables
until a reply packet comes back. Entries in port tables depend upon the
destination. See the description of primary ports on page 113.
Broadcast and multicast packets.
Broadcast and multicast packets go to the
primary port of each CrossLink.
Link failure.
If one link in a CrossLink fails, a trap is sent and the entire
CrossLink connection is disabled.