Olicom 8600 Switch User Manual


 
155
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641 Monitoring the Network with the Console
Receive Buffer Overflows
Total number of frames received on this port which caused a buffer overflow.
Transmit Buffer Overflows
Total number of frames which could not be transmitted from this port because of
transmit buffer overflow.
Long Frames
Total number of frames received on this port which exceeded the maximum frame
length.
Short Frames
Total number of frames received on this port which were less that 18 bytes.
Duplicate Ring Number
Indicates the number of times a frame which contains a duplicate ring number in
the RIF field has been seen by the port.
Invalid RIF RC Field
Indicates the number of times a frame which contains an illegal Routing Control
field has been seen by the port.
RIF Length Exceeded
Indicates the number of times a frame which contains a RIF field which is too long
has been seen by the port.
Explorer Overflow
Indicates the number of times that an explorer frame has been dropped because of
explorer rate throttling.
Ring Number Mismatch
Indicates the number of times that an incoming frame did not correctly include the
port’s ring number.
Config Loss
Number of configuration loss events after the port has completed the join process
and then lost communication.
Config Loss Reason
Latest Config Loss error code. Possible values are:
None
Wire Fault
- Wire fault.