Olicom 8600 Switch User Manual


 
iii
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Modifications
If the device is changed or modified without the express approval of Olicom A/S the user may void his
or her authority to operate the equipment.
Safety Notices
Danger:
To avoid shock hazard, do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguring of the CrossFire 8600 Token-Ring Switch and/or the CrossFire 8605
Token-Ring Fiber Switch during an electrical storm.
Danger:
To avoid the possibility of electrical shock, switch power off and unplug the power cord from
the outlet before detaching the power cord from the CrossFire 8600 Token-Ring Switch and/or the
CrossFire 8605 Token-Ring Fiber Switch.
Danger:
Do not open the CrossFire 8600 Token-Ring Switch and/or the CrossFire 8605 Token-Ring
Fiber Switch. Dangerous voltages inside.
Danger:
To avoid shock hazard the power cord must be connected to a properly wired and earthed
receptacle. Any equipment to which the CrossFire 8600 Token-Ring Switch and/or the CrossFire 8605
Token-Ring Fiber Switch will be attached must also be connected to properly wired and earthed
receptacles.
Caution:
Observe the following power cable considerations before you begin installation of the CrossFire 8600
Token-Ring Switch and/or the CrossFire 8605 Token-Ring Fiber Switch.
1. The socket outlet shall be installed near the equipment and shall be easily accessible.
2. To prevent electrical shock, the power cord set used must comply with national regulations.
2a. The female receptacle of the cord must meet CEE-22 requirements.
2b. The cord must be UL listed, CSA labelled, and consist of three conductors with a maximum
of 15 feet in length.
Type SVT or SJT cord sets shall be used for units which stand on a desk or table. Type SJT
cord sets shall be used for units which stand on floor.
2c. The male plug for units operating at 115 VAC shall consist of a parallel blade, grounding
type attachment plug rated 15 A, 125 VAC.
The male plug for units operating at 230 VAC shall consist of a tandem blade, grounding
type attachment plug rated 15 A, 250 VAC.
The male plug for units operating at 230 VAC (outside of the United States and Canada) shall
consist of a grounding type attachment plug rated 15 A, 250 VAC and have the appropriate
safety approvals for the country in which the equipment will be installed.
Caution:
Support the CrossFire 8600 Token-Ring Switch and/or the CrossFire 8605 Token-Ring Fiber
Switch while you are installing the unit to avoid dropping it on the floor or any equipment beneath it in
the rack. The CrossFire 8600 Token-Ring Switch unit and the CrossFire 8605 Token-Ring Fiber Switch
unit each weighs approximately 8.8 kg (19.4 lbs).
Warning:
All RJ45 connectors must only be connected to safety extra low voltage (SELV) circuits like
local area networking (LAN).