Olicom 8600 Switch User Manual


 
66
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641 Installation
Control Panels
The following tables list and describe the connectors, switches and status LEDs on
the switch.
Front Panel
Table 17 and Table 18 list the front panel controls on the switch.
Connectors and Push-Buttons
Name Description
Ports 1 to 20
CrossFire 8600:
UTP/STP Token-Ring ports with RJ-45 jacks.
— Ports 19 and 20 can attach to a MAU/CAU RI/RO port.
CrossFire 8605:
Fiber Token-Ring ports using VF-45 connectors.
— All 20 fiber ports can attach to a MAU/CAU RI/RO port.
— On CrossFire 8605, UTP/STP connections are only
available via the CrossFire 8610 Token-Ring UEM.
MANAGEMENT Console connection with DB-9 connector.
RST Reset—full system reset of software and hardware.
SYS REQ
(unlabeled)
System Request—initiates a set of system request menus on
the attached console. If depressed for more than 5 seconds,
the switch will accept download of the main image from the
serial port via the X-modem protocol.
Table 17. Front Panel Connectors and Push-Buttons