Panasonic DX-2000 Printer User Manual


 
73
022 SUBSTITUTE RCV
1 Invalid
Selecting whether the machine receives to memory when
recording paper runs out, toner runs out or recording paper is
jammed.
2 Valid
024 PRINT REDUCTION
1 Fixed
Selecting print reduction mode.
Fixed: Reduce received document according to setting of
Parameter No. 025.
Auto: Reduce received document according to the length of
received documents.
2Auto
025 REDUCTION RATIO 70 70% Selecting fixed print reduction ratio from 70% to 100%. This
parameter functions only when fixed print reduction is selected on
Fax Parameter No. 024.
---- ----
100 100%
026 POLLING PASSWORD (----) Setting a 4-digit password for secured polling. (See page 151)
028 STAMP AT MEM. XMT 1 Invalid Selecting whether the machine stamps the original documents
when storing the documents into memory.
(depending on the Stamp setting on the Control Panel)
2 Valid
030 DRD SERVICE
1 Invalid
Selecting whether or not the machine is available "DRD Service".
If this parameter is set to "Valid", your machine detects the
specified ring pattern only to receive a document automatically.
2 Valid
031 INCOMPLETE FILE SAVE 1 Invalid Selecting whether the machine retains the document in memory if
the document is not successfully transmitted.
2 Valid
032 COPY REDUCTION
1 Manual
Selecting whether the machine performs the copy reduction ratio
automatically or manually.
Manual : The machine will prompt you for the Zoom ratio (100% to
70%) when making copies.
Auto : The machine will automatically determine the reduction
ratio according to the length of the original document.
2Auto
033 XMT REDUCTION 1 Invalid Selecting whether the machine performs reduction when the
transmitting document is wider than the recording paper used at
the receiving machine.
2 Valid
034 ENERGY SAVER MODE
1 Off
To reduce the power consumption in standby, specify the Delay
Time (1 to 120 minutes) for the machine to enter into the Energy-
Saver mode.
Off : The unit will remain in standby mode and
consume more energy than when in
Energy-Saver.
Energy-Saver Mode :Saves energy by consuming less power
than when in standby mode by turning off
the fuser unit after the specified time.
2 Energy-Saver
035 DAYLIGHT TIME
1 Invalid
Selecting whether the clock adjusts for Daylight Saving Time
automatically. The built-in clock will advance 1 hour at 2:00 am on
the first Sunday in April and fallback 1 hour at 2:00 am on the last
Sunday in October.
2 Valid
Continued on the next page...
No. Parameter
Setting
Number
Setting Comments
Customizing Your Machine
3