Panasonic PT-EZ580 PT-EW640 PT-EX610 PT-EW540 PT-EX510 Projector User Manual


 
Chapter 4Settings — [NETWORK] menu
120 - ENGLISH
Contents of E-mail sent
Example of E-mail sent when E-mail is set
The following E-mail is sent when the E-mail settings have been established.
=== Panasonic projector report(CONFIGURE) ===
Projector Type : EZ580
Serial No : SN9250024
----- E-mail setup data -----
TEMPERATURE WARNING SETUP
MINIMUM TIME at [ 30] minutes interval
INTAKE AIR TEMPERATURE Over [ 36 degC / 96 degF ]
ERROR [ ON ]
LAMP RUNTIME [ ON ] at REMAIN [ 400] H
LAMP RUNTIME [ ON ] at REMAIN [ 500] H
INTAKE AIR TEMPERATURE [ ON ]
PERIODIC REPORT
Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ OFF ]
Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ]
00:00 [ OFF ] 01:00 [ OFF ] 02:00 [ OFF ] 03:00 [ OFF ]
04:00 [ OFF ] 05:00 [ OFF ] 06:00 [ OFF ] 07:00 [ OFF ]
08:00 [ OFF ] 09:00 [ OFF ] 10:00 [ OFF ] 11:00 [ OFF ]
12:00 [ OFF ] 13:00 [ OFF ] 14:00 [ OFF ] 15:00 [ OFF ]
16:00 [ OFF ] 17:00 [ OFF ] 18:00 [ OFF ] 19:00 [ OFF ]
20:00 [ OFF ] 21:00 [ OFF ] 22:00 [ OFF ] 23:00 [ OFF ]
----- check system -----
MAIN CPU BUS [ OK ]
FAN [ OK ]
INTAKE AIR TEMPERATURE [ OK ]
AROUND LAMP TEMPERATURE [ OK ]
LAMP REMAIN TIME [ OK ]
LAMP STATUS [ OK ]
APERTURE(CONTRAST-SHUTTER) [ OK ]
SHUTTER(MUTE-SHUTTER) [ OK ]
INTAKE AIR TEMP.SENSOR [ OK ]
AROUND LAMP TEMP.SENSOR [ OK ]
BATTERY [ OK ]
AIRFLOW SENSOR [ OK ]
LENS MOUNTER [ OK ]
COVER OPEN [ OK ]
PRESSURE SENSOR [ OK ]
ANGLE SENSOR [ OK ]
FILTER UNIT [ OK ]
AIR FILTER [ OK ]
(Error code00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)
Intake air temperature : 45 degC / 113 degF
Around lamp temperature : 42 degC / 107 degF
PROJECTOR RUNTIME 2500 H
LAMP ECO 100 H
LAMP NORMAL 200 H
LAMP REMAIN 1900 H
-------- Current status --------
MAIN VERSION 1.00
NETWORK VERSION 1.00
SUB VERSION 1.00
LAMP STATUS LAMP=ON
INPUT SIGNAL HDMI
SIGNAL NAME XGA60
SIGNAL FREQUENCY 65.4kHz / 54.4Hz
REMOTE2 STATUS ENABLE
----- Wired Network configuration -----
DHCP Client OFF
IP address 192.168.0.8
MAC address cc:7e:e8:00:00:00
Tue Jun 04 22:30:14:2013
----- Memo -----
Note