r Projector control command (with sub command)
Command Sub command Details Remark
VXX LPWI1 Lamp power selection
+00001=NORMAL,+00000=ECO, +00030=AUTO
VXX RYCI2 RGB2 input setting +00000=RGB/YP
B
P
R
, +00001=Y/C, +00002=VIDEO
r Lens control command
Command Sub command Details Remark
VXX LNSI2 Lens H shift
+00000=Fine adjustment 1+, +00001=Fine adjustment 1
-
,
+00100=Fine adjustment 2+, +00101=Fine adjustment 2
-
,
+00200=Coarse adjustment+, +00201=Coarse adjustment
-
VXX LNSI3 Lens V shift
VXX LNSI4 Lens focus
VXX LNSI5 Lens zoom
<REMOTE 2 IN> terminal
It is possible to control the projector remotely (by external contact) from a control panel located away from the projector where remote control
signals cannot reach.
Use the <REMOTE 2 IN> terminal on the connecting terminals of the projector to connect to the control panel.
Remote control Contact control
Remote control/contact control
Standby Lit
Lamp
RGB1 VIDEO
RGB2 HDMI
DVI-D
Installation locations in meeting rooms, etc.
Remote control board in another location
Pin assignments and signal names
D-Sub 9-pin
Outside view
Pin No. Signal name Open (H) Short (L)
(9) (6)
(5) (1)
(1)
GND ― GND
(2)
POWER OFF ON
(3)
RGB1 Other RGB1
(4)
RGB2 Other RGB2
(5)
VIDEO Other VIDEO
(6)
HDMI Other HDMI
(7)
DVI-D Other DVI-D
(8)
SHUTTER
*1
OFF ON
(9)
RST/SET
Controlled by remote
control
Controlled by external
contact
*1 For PT-EZ580, PT-EW640 and PT-EX610
[AV MUTE] for PT-EW540 and PT-EX510
Attention
f When controlling, make sure to short-circuit pins (1) and (9).
f When pins (1) and (9) are short-circuited, the following buttons on the control panel and the remote control are disabled. Commands for
RS-232C and network functions corresponding to these functions are also disabled.
g Power <v/b> button on the control panel or the power on <b> button, power standby <v> button, and <SHUTTER> button and <AV
MUTE> button on the remote control
f When pins (1) and (9) are short-circuited, and then any pins from (3) to (7) and the pin (1) are short-circuited, the following buttons on the
control panel and the remote control are disabled. Commands for RS-232C and network functions corresponding to these functions are also