Panasonic PT-EZ580 PT-EW640 PT-EX610 PT-EW540 PT-EX510 Projector User Manual


 
Chapter 5Maintenance — Maintenance/replacement
130 - ENGLISH
Cleaning the air lter unit
Remove the air lter unit beforehand according to the previously described procedure in “Removing the air lter unit”.
Fig. 1 Fig. 2
1) Wash the air filter unit. (Fig. 1)
i) Soak the air filter unit in cold or warm water and then lightly rinse it.
f Do not use cleaning tools such as brushes.
f When rinsing, hold the frame of the air lter unit without putting strong pressure on the lter.
ii) Rinse the air filter unit two to three times using fresh water each time.
f Insufcient rinsing may result in odors.
2) Dry the air filter unit. (Fig. 2)
f Let the air lter unit naturally dry off in a well-ventilated place where there is little dust and is not exposed to direct sunlight.
f Do not dry using drying devices such as dryers.
f After the air lter unit is dried, proceed to “Attaching the air lter unit” (x page 130).
Attaching the air lter unit
1) Attach the air filter unit to the projector.
f Perform Step 2) in “Removing the air lter unit” in the reverse order.
f Push in the air lter unit securely until it clicks into place.
2) Attach the air filter cover.
f Perform Step 1) in “Removing the air lter unit” in the reverse order to close the air lter cover, and push in the air lter cover securely
until it clicks into place.
f Use a Phillips screwdriver to rmly tighten the air lter cover xing screw (x1).
Attention
f After washing the air lter unit, dry it thoroughly before attaching it back to the projector. Attaching a wet unit will cause an electric shock or
malfunction.
f Do not disassemble the air lter unit.
f Make sure that the air lter unit is properly attached before using the projector. If it is not attached, the projector will suck in dirt and dust
causing a malfunction.
Note
f If you use the projector without attaching the air lter unit, the lter indicator <FILTER> ashes in red and the message appears on the
projected image for approximately 30 seconds.
f Replace the air lter unit with the new optional Replacement Filter Unit (Model No.: ET-RFE300) if it is damaged or if the dirt does not come
off even after washing.
f Air lter replacement is recommended after cleaning the unit two times.
f The dust-proof properties may be reduced after each cleaning.