1. About the FrameSaver SLV
1-12
September 2002 9128-A2-GB20-80
NetScout Manager Plus and NetScout Probes
Provides complete LAN and WAN traffic analysis and monitoring functions for
FrameSaver devices.
The following features are supported using this application:
Thresholds for RMON 1 (Remote Monitoring, Version 1) alarms and events
can be configured.
Performance monitoring can be performed using collected RMON 2
(Version 2) data. NetScout Manager Plus’s Protocol Directory and Distribution
functionality allows FrameSaver devices to measure up to eleven
network-layer protocols and report the amount of traffic generated by each. Its
IP Top Talkers and Listeners reporting identifies the devices using network
bandwidth for traffic and protocol analysis, identifying the network’s top six
users. In addition, it collects performance statistics from FrameSaver devices.
Up to 900 samples can be stored in 15-minute buckets, with 96 buckets in a
24-hour period, for up to five days worth of data.
Optional standalone NetScout Probes can be used with FrameSaver devices
at sites where full 7-layer monitoring, an unlimited number of protocols, and
advanced frame capture and decode capabilities are desired.