Paradyne 9126 Network Router User Manual


 
B. SNMP MIBs and Traps, and RMON Alarm Defaults
9128-A2-GB20-80 September 2002
B-19
Rising Event Operation
If a rising threshold is crossed during the interval shown in a table (e.g., frames
dropped by the network), the event is armed and an alarm is generated at the end
of the interval. Only one alarm per event per interval is generated. The alarm
condition persists until the event has been disarmed (reset).
The event is disarmed when a falling threshold has been crossed and the rising
threshold has not been crossed during an interval, allowing the event to return to
its original disarmed state.
Physical Interface Alarm Defaults
This alarm only applies to the FrameSaver units network interface.
Table B-10. Network Physical Interface Alarm Defaults
Item
Sample
Type
1
MIB/Tag/OID
2
Interval Event Type
Rising
Threshold
Default
Falling
Threshold
Default
Unavailable
Seconds
D
MIB:
DS1/E1 MIB (RFC 1406)
Tag:
dsx1TotalUASs
OID:
.1.3.6.1.2.1.10.18.9.1.5.
I
900 secs
(15 mins)
Rising 1 1
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is
contained in the MIB.
2
I
in the OID = Interface ID of the frame relay link.