Paradyne 9126 Network Router User Manual


 
B. SNMP MIBs and Traps, and RMON Alarm Defaults
9128-A2-GB20-80 September 2002
B-15
enterpriseSecondary-
ClockFail(4)
devLastTrapString
(devHealthAndStatus.-
mib)
Operating software has detected
that the secondary clock source
has failed.
String:
Secondary clock failed.
enterpriseSecondary-
ClockFailClear(104)
Operating software has detected
that the secondary clock source is
operational again.
String:
Secondary clock restored.
enterpriseSelfTest-
Fail(2)
devLastTrapString
(devHealthAndStatus.-
mib)
Unit has completed
(re)initialization and a hardware
failure was detected.
String:
Self test failed: $
s
. ($
s
is the
contents of devSelfTestResult.)
enterpriseTest-
Start(5)
For physical interfaces and
frame relay links:
ifIndex (RFC 1573)
.0.0 (placeholder)
devLastTrapString
(devHealthAndStatus.-
mib
For virtual circuits (DLCIs):
devFrExtDlciIfIndex
(devFrExt.mib)
devFrExtDlciDlci
(devFrExt.mib)
devLastTrapString
(devHealthAndStatus.-
mib
At least one test has been started
on an interface or virtual circuit.
String:
$testString test started on
$ifString. (e.g., DTE Loopback
test started on Sync Data Port
S01P1.)
enterpriseTest-
Stop(105)
All tests have been halted on an
interface or virtual circuit.
String:
$testString test stopped on
$ifString. (e.g., Disruptive PVC
Loopback test stopped on DLCI
100 of Sync Data Port S01P1
frame relay.)
Table B-7. enterprise-Specific Traps and Variable-Bindings (3 of 3)
Trap Variable-Bindings Possible Cause