Paradyne 9126 Network Router User Manual


 
10. Setting Up NetScout Manager Plus for FrameSaver Devices
10-14
September 2002 9128-A2-GB20-80
Procedure
1. Open a terminal window and go to
$NSHOME/usr
.
2. Copy an example or interface-specific file to a new file that contains the user
history table number.
3. Open the new file using a text editor.
The variables in the file are listed with their OIDs (Object IDs). The frame relay
interface number 101015001 must replace @IFN, and the DLCI number to be
monitored must replace @DLCI.
Example:
frCircuitSentFrames
Change
1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI
to
1.3.6.1.2.1.10.32.2.1.6.101015001.301
The only valid interface number for a FrameSaver SLV 9126, 9126-II, 9126-II
Router, or 9128-II is 101015001.
4. Edit the new file, as needed.
Refer to
Creating .UDH Files
and
Using Custom History
in the
NetScout Manager
Plus User Guide
for additional information.
See Appendix B,
SNMP MIBs and Traps, and RMON Alarm Defaults
, for OID
information for an interface.