DSLAM Connections with remote CPE units 45
Model 3201 G.SHDSL Integrated Access Device User Guide 4 • Basic Application Configurations
– VPI = 0
– VCI = 300
– LLC header mode = off
– HDLC header mode = off
– No authentication
– Leave User name and Password blank.
Click on
Apply.
3. Go to G.SHDSL in the Configuration Menu, then the submenu Configuration.
Change Terminal Type to Remote and Interface Type to atm. Click on the
Configure button.
In the Action submenu under G.SHDSL, change Action to
Deactivate, then click on Action.
Return to Action, select
Start and click on Action.
Model 3201 (Central)Configuration Steps (PPPoA Bridged)
From the command line interface (CLI) via the RS-232 control port,
→
ip list interfaces
One IP interface is called ip1 with an IP address of 192.168.1.1
Change the IP address so it is in the same subnet as both PCs. For example, to 192.168.100.3
→
ip set interface ip1 ipaddress 192.168.100.3 255.255.255.0
1. Now you can bring up the web-page management system on your browser by entering the IP address of
the 3201.
2. On the Menu, go to Configuration, then to WAN Connections. Delete the factory default WAN services
already defined.
Click on
Create a new service in the main window, select PPPoA_Bridged and click on the Configure button.
In the Description field, enter the description you wish. In this example, it is called PPPoA Bridged.
– VPI = 0
– VCI = 300
– LLC header mode = off
– HDLC header mode = off