Pelco CM6800E-48X8 Printer User Manual


 
22 C1528M-F (6/05)
KBD100, KBD200A, AND KBD300A SERIES KEYBOARDS
You can connect up to eight KBD100/200A/300A Series keyboards to any of the following ports:
COM 5 (1 direct-powered keyboard or up to 8 remotely connected keyboards)
COM 6 (1 direct-powered keyboard or up to 8 remotely connected keyboards)
COM 7 (up to 8 remotely connected keyboards)
COM 8 (up to 8 remotely connected keyboards)
The total number of KBD100/200A/300A Series keyboards connected to the CM6800E cannot exceed 16.
KBD100, KBD200A, and KBD300A: Direct-Powered Keyboards
Use COM 5 and 6 (Serial Ports 5 and 6) for direct-powered local keyboards. Each port can power one KBD100/200A/300A Series keyboard.
If you are connecting more than one keyboard to COM 5 or 6, a KBDKIT(-X) is required for each keyboard. Refer to the
KBD100, KBD200A,
and KBD300A: Remote Keyboards
section.
1. Using the 25-foot (7.62 m) straight data cable supplied with the keyboard, plug one end into the RJ-45 connector on the rear of the
keyboard.
NOTE: If distance between CM6800E and keyboard exceeds 25 feet, use KBDKIT(-X).
Figure 14. Data Cable Plugged into Local Keyboard
2. Plug the other end of the data cable into either COM 5 or 6 on the CM6800E.
DEFAULT (ADDRESS 0) DIP SWITCH SETTING
S
(SHIPPED FROM FACTORY)
DIP SWITCHES 1-8 OFF
KBD300A
Figure 15. Data Cables Plugged into COM 5 and 6
1
2
3
4
5
6
7
8
16
876
3231
432
120/230~
50/60 HZ
25 WATTS
12345678
CONTROL
AT
+
T
-
R
+
R
-
T
+
T
-
R
+
R
-
B
1
2
F
3
1
010101
KBD100, 200A, 300A
RJ-45 PIN-OUTS
1 Tx+
2 Tx-
3 12V
4 12V
5 GROUND
6 NC
7 Rx-
8 Rx+
CM6800E-48X8
COM 5&6
1 Rx+
2 Rx-
3 KBD 12V
4 KBD GROUND
5 GROUND
6 NC
7 Tx-
8 Tx+
KBD100, KBD200A, KBD300A
KBD100, KBD200A, KBD300A