PROGRAMMING THE CM6800E
The CM6800E is shipped from the factory with default programming settings. If the defaults are acceptable, the CM6800E can be
operated without any user programming. However, you may want to program the following basic system settings:
•Time and date
Camera titles
PTZ control via hardwire data connections
Alarm contacts
Alarms must be enabled before they are functional.
Access
All access is set to YES by factory default.
Communication ports
To connect remote keyboards as shown in the Quick Start Guide, change the settings for Port 7 or 8.
Pelco provides two options for programming the CM6800E to your specifications:
Password-protected, on-screen programming screens accessible directly from the Matrix Switcher
PC-based CM6800-MGR software
Refer to the CM6800-MGR Quick Start Guide for instructions on accessing and using this software to program your system.
NOTE: Pelco strongly recommends uploading your programming settings to the CM6800-MGR to save settings in the event of an
accidental reset.
The CM6800E allows system programming from only one monitor at a time. If programming from the CM6800-MGR is sent to the
CM6800E at the same time that you are programming from a monitor screen, the system will exit the on-screen programming function.