Pioneer DRM-604X Computer Drive User Manual


 
Appendix A Troubleshooting IBM- PC DOS / WINDOWS Installation
Owner’s Manual / Software Driver Installation Guide A-11
BUSY light Flashes
at one-second
intervals
1. This is a visual indicator from the drive that something is
wrong with the drive, affecting its ability to perform. It may be a
mechanical problem. Or, the drive may be in test mode.
2. Make sure the switch for Test Mode is DOWN/OFF. Refer to
Operating Instructions. For almost all DOS applications, only the
terminator switch on the DRM-602X should be up. All others on the
DRM602X and all switches on the DRM604X should be down.
1. It you are not booting from a SCSI hard drive using this SCSI
interface card card, and if there is a boot ROM on the interface
card, the boot ROM should be removed or disabled using software
options.
2. If booting from a SCSI Hard drive, make sure the SCSI IDs do
not conflict and that termination on the SCSI interface card is
disabled. Consult documentation for interface card manufacturer.
NOTE: The hard drive should be terminated as the first device on the
chain and if the the Pioneer Changer is the only other device on the line
,
it should also be terminated.
Boot problems or the
unit only accesses
Drive D
3. Verify that the Pioneer Changer is functioning properly. Refer to
TB #168 to run a Self-Test on the unit and to TB #169 to run an Audio
Play test. These documents are available as 32 169 & 32 170 on the
Pioneer LaserFacts System; see Appendix F.