Electrical Requirements
The following electrical requirements must be met:
Power consumption: 8V/500 mA
Typical power consumption: 5W per unit
The supplied power for the AC adaptor power supply must be 110 to 240
ac nominal, 50/60 Hz.
KIRK Base Stations and KIRK Repeaters
Environmental Requirements
Avoid installing base stations and repeaters on large concrete or marble
columns because these columns affect radio coverage. If possible, place the
base station a minimum of one meter/3.3 feet from these types of columns.
Do not install a base station or repeater with the antenna housings near
metal objects. Be careful not to damage existing wiring or panels.
Do not position base stations and repeaters in ducts, plenums, or hollow
spaces used to transport environmental air except where the duct, plenum
or hollow space is created by a suspended ceiling having lay-in panels.
When you need more than one base station in a cell to meet traffic
requirements, position the base stations at the same cell center.
Keep the base station and repeater away from steel constructions.
Do not position base stations and repeaters directly on metallic surfaces. If
possible, place the base station a minimum of one meter/3.3 feet from
these types of surfaces.
Do not position base station and repeaters behind furniture.
Only position base stations and repeaters where the signal is needed.
The installation area must be clean, free of traffic and excess dust, dry, and
well ventilated.
The installation area must be within the temperature ranges of 10°C and
40°C/50°F and 104°F.
The installation area must be between 20% and 80% non-condensing
relative humidity.