Powerware BD Switch User Manual


 
Appendix
ConnectUPS Web/SNMP Card (X and BD Models) User’s Guide : Rev A www.powerware.com
32
DIP Switch Description
DIP switch definitions for both types of the ConnectUPS
Web/SNMP Cards are listed in Table 4.
Table 4. DIP Switch Modes
SW1 SW2 Description
Off Off Operational Mode (default)
Off On BOOTP/DHCP Enable Mode (overrides the serial/Telnet
configuration)
On Off Reserved
On On Reserved
Jumper 1 (JP1) Settings
The JP1 jumper is found on both the ConnectUPS-X and
ConnectUPS-BD. The JP1 pins are NOT jumpered by
factory-default. Table 5 shows the jumper definitions.
Table 5. JP1 Definitions
Jumper Setting Definition
1 and 2 Allows
admin
to be entered as the password when the
programmed Superuser password has been forgotten
3 and 4 Disables all changes to the card’s configuration
NOTE On the ConnectUPS-BD, jumper positions 5 and 6, 7 and 8 are undefined;
DO NOT jumper these positions.