Renesas FLASH Development Toolkit 3.07 Computer Hardware User Manual


 
24
3.4.5 Connection Type
Select whether the connection is for Boot Mode or User Mode in the ‘Connection Type’ dialog.
Additionally, for a connection to a kernel that is still running on the device from a previous session, select
the ‘Kernel already running’ check box. Next, select the communication speed (bps) if the default value is
not correct or not present. Speeds where the target error rate is greater than 4%, or the FDM\E8Direct error
rate is greater than 0% are automatically removed from the recommended list. When using the
FDM\E8Direct the ‘User Specified’ connection speed option is enabled; when selected, this allows the user
to specify a non-standard baud rate. The error rate will be displayed – this takes into account the target
peripheral clock rate, the target Bit Rate Register calculation formula, and the FDM\E8Direct
characteristics.
Click the ‘Next’ button to continue.
Figure 3-6 Connection Type
Note that ‘Use Default’ is designed for use with the Renesas Evaluation Board or Evaluation Development
Kits. Uncheck this to allow manual selection of the bit rate.