Renesas M3062NT3-RPD-E Network Card User Manual


 
( 42 / 84 )
(1) Connecting to a 100-pin LCC Socket
To connect the M30800T-PTC (included) to the 100-pin LCC socket (IC61-1004-051 by Yamaichi
Electronics Co., Ltd.) on the target system, following the procedure below.
(1) Attach the CN2 side of the M30800T-PTC to the tip (CN2 side) of the pitch converter board
connected to the emulation pod probe.
(2) Attach the M30800T-PTC to the 100-pin LCC socket.
Figure 3.13 Connecting to a 100-pin LCC socket
CAUTION
Notes on Connecting the Target System:
Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
The connector of the IC61-1004-51 is guaranteed for only 20 insertion/removal
iterations.
For purchasing the IC61-1004-51 or for technical information, contact Yamaichi
Electronics Co., Ltd. (http://www.yamaichi.co.jp/e/index.shtml)
M30800T-PTC
CN2 side
100-pin LCC socket
Target system
No. 1 pin
(2)
(1)
Tip of pitch converter board
Tip of emulation pod probe