Renesas M3062NT3-RPD-E Network Card User Manual


 
( 49 / 84 )
Figure 3.20 Connecting to a 100-pin 0.5-mm-pitch foot pattern (part 2)
CAUTION
Notes on Connecting the Target System:
Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
The connector of the M3T-100LCC-QSD is guaranteed for only 20 insertion/
removal iterations.
(8) Connecting to a 100-pin 0.5-mm-pitch Foot Pattern (Part 2)
Here follows how to connect the emulation pod probe to a 100-pin 0.5-mm-pitch foot pattern on the
target system with the M3T-100LCC-QSD (not included). For details on the M3T-100LCC-QSD
(not included), refer to its user's manual.
(1) Mount the TQPACK100SD to the target system.
(2) Attach the TQSOCKET100SDG to the TQPACK100SD.
(3) Attach the M3T-100LCC-QSD to the TQSOCKET100SDG.
(4) Attach the CN2 side of the M30800T-PTC to the tip (CN2 side) of the pitch converter board
connected to the emulation pod probe.
(5) Attach the M30800T-PTC to the M3T-100LCC-QSD.
100-pin 0.5-mm-pitch (100P6Q-A) foot pattern
CN2 side
M30800T-PTC
M3T-100LCC-QSD (not included)
TQSOCKET100SDG
TQPACK100SD
Target system
No. 1 pin
(3)
(1)
(2)
(4)
(5)
Tip of pitch converter board
Tip of emulation pod probe
These three parts are in one package.