29
4. Troubleshooting
Error & Status Messages on the Operation Panel
Message Description Comments
ADD FUSER OIL The fuser oil bottle is empty. Replace the fuser oil bottle.
⇒
P.50
“Replacing the Fuser
Oil Bottle and Ozone Filter”
CALL SERVICE
SC:nn
There is a malfunction in the
printer.
Turn the printer off and on.
If this doesn't clear the prob-
lem, contact your sales or
service representative.
CHECK CHARGER The charger is not set cor-
rectly or the charger cleaner
is not in the correct position.
Set the charger correctly.
⇒
P.53
“Replacing the Waste
Toner Bottle and Charger”
CHECK FUSING
UNIT
The fusing unit is not in-
stalled in the printer.
Contact your sales or service
representative.
CHECK PCU The photoconductor unit is
not installed in the printer.
Install the photoconductor
unit.
⇒
P.48
“Replacing the
Photoconductor Unit”
CHECK TONER
CARTRIDGE
The toner cartridge is not in-
stalled correctly.
Install the cartridge correct-
ly.
⇒
P.45
“Replacing the
Toner Cartridge”
CHECK WASTE
TONER BOTTLE
The waste toner bottle is not
installed.
Install the waste toner bot-
tle.
⇒
P.53
“Replacing the
Waste Toner Bottle and Charg-
er”
CHECK (tray name) The paper tray is not in-
stalled correctly.
Install the paper tray cor-
rectly.
The tray on the paper feed-
ing path was not set correct-
ly when the printer received
the print job.
Install the paper tray cor-
rectly. The printer will re-
start printing automatically.
CLOSE
FRONT COVER
The front cover is open. Close the front cover.
(
⇒
P.1)
CLOSE
LEFT COVER
The left cover is open. Close the left cover. (
⇒
P.1)
CLOSE PAPER EXIT
COVER
The paper exit cover is open. Close the paper exit cover.
(
⇒
P.3)