Changing the Settings of Service Programs
65
3
Entering decimal values in SP No. 160–162:
• Press the {
Program
} key to enter a decimal point.
• Press the {q} key to fix the value.
160 Side Ers. Adjust the default side edge margin width in Edge
Erase and Centre/Edge Erase mode.
Note
❒ Default:
• Metric Version: 5mm
• Inch Version: 0.2"
❒ Adjustable value:
• Metric Version: 2 – 20mm
• Inch Version: 0.1" – 0.8"
161 Center Ers. Adjust the default Centre margin width in Centre/
Edge Erase mode.
Note
❒ Default:
• Metric version: 10mm
• Inch version: 0.4"
❒ Adjustable value:
• Metric version: 4 – 60mm
• Inch version: 0.2" – 2.3"
162 Horizontal Ers. Adjust the default horizontal edge (top and bottom)
margin in Edge Erase and Centre/Edge Erase mode.
Note
❒ Default:
• Metric version: 5mm
• Inch version: 0.2"
❒ Adjustable value:
• Metric version: 2 – 20mm
• Inch version: 0.1" – 0.8"
170-172 Ers.**1
L
Ers.**2
L
Ers.**3
L
Set up and register three original sizes for when per-
forming edge erase of non-standard size originals, or
performing centre frame erase.
Note
❒ Default: 0
×
0mm
❒ Adjustable value: 100-257mm × 100-364mm
SP No. Mode Function