Schneider Electric KVM2132P Switch User Manual


 
93KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Update Adapter Display Info. Read display information (ex: brand/type/EDID) for monitor. Write
display information to server modules so that computers can identify the monitor connected at console
ports. This is only necessary to set to unique resolution level provided by the monitor.
Firmware Upgrade Recovery
If the switch's main firmware upgrade procedure fails, and the switch becomes unusable:
1. Power off the switch.
2. Press and hold the Reset Switch in (see page 7).
3. While holding the Reset Switch in, power the switch back on.
The switch reverts to the original factory installed main firmware version. Once the switch is
operational, try the upgrade again.
Adapter Firmware Upgrade Recovery
If the adapter firmware upgrade procedure fails for one of the KVM Adapter Cables and the adapter
becomes unusable:
1. Unplug the Adapter from the server it is connected to.
2. Slide its Firmware Upgrade Recovery Switch (located next to the Cat 5e connector) to the
RECOVER position.
3. Plug the Adapter back into the server.
4. Repeat the Adapter upgrade procedure.
5. After the Adapter has been successfully upgraded, unplug the Adapter from the server.
Slide the Firmware Upgrade Recovery Switch back to the NORMAL position.
Plug the Adapter back into the server.
Backup/Restore
Backup
1. Enter a password for the file in the Password field.
Note: 1. A password is optional. If one has not been set, the file can be restored
without specifying a password.
2. If a password is set, make a note of it. It is necessary to restore the file.
2. Click Backup.
3. When the browser asks what to do with the file, select Save to disk. (Save in a convenient
location.)
Restore
1. Click Browse, navigate to the file, and select it.
Note: If you renamed the file, there is no need to return it to its original name.
2. If you set a password when you created the file, enter it.
3. Select the options to restore.
4. Click Restore.
After the file is restored, a message appears to inform you that the procedure succeeded.