Schneider Electric KVM2132P Switch User Manual


 
109KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Fan Location and Speed Information
KVM2132P / KVM2116P only
Fan Location
The KVM switch has 4 fans that feed realtime fan speed information to the WinClient / Java Client
Device Management page. The fan speed is shown on the Device Information web page.
Fan Speed
Fan speed automatically adjusts according to temperature as follows:
If any sensor senses that the temperature is greater than 32° C, all fans spin at half speed .
If any sensor senses that the temperature is greater than 45° C, all fans spin at full speed.
When all four sensors sense that the temperature is less than 40° C, all fans return to half speed.
When all four sensors sense that the temperature is less than 30° C, all fans turn off.
Note: Fan half speed equals 2500 rpm. Fan full speed equals 5000 rpm.
Temperature Sensor Location and Information
KVM2132P / KVM2116P only
The KVM switch has 4 temperature sensors on its mainboard that feed realtime temperature updates to
the WinClient / Java Client Device Management page. See Device Information, Temperature on page 67
for more information.
Note: The temperature inside the case can be higher than the ambient temperature (0-50° C).
IC chips can tolerate temperatures of up to 105°C. If the temperature reading rises past 85° C,
make the ambient temperature cooler or, shut the switch down until it cools off.
KVM-SERIAL Server Module Configuration and
Operation
The KVM-SERIAL cable connects a serial device to the KVM switch.
Configuration
To configure the KVM-SERIAL Server Module to interact with the connected device, set its serial
parameters to match the parameters of the device:
1. In the Port Access page Sidebar, select the port to which the KVM-SERIAL Server Module is
connected.
2. Select Port Configuration on the menu bar. The page opens with the Port Properties tab
selected.