(10) Height expansion for enlarged characters: DC4 DC4 h
Format: ASCII DC4 DC4 hn
Hex 14 14 68 n
Decimal 20 20 104 n
Function: Specifies the height expansion of enlarged characters.
0
n
127
The MSB of the parameter is masked.
If n = 0, the expansion specified in the setup mode is selected.
Enlarged character cell expansion takes priority over height expansion. If
the height expansion exceeds the cell expansion when enlarged character
data is input, the characters are enlarged to the cell expansion.
The default setting is the expansion specified in the setup mode.
(11) HMI for enlarged characters: DC4 DC4 i
Format: ASCII DC4 DC4 i n1 n2
Hex 14 14 69 n1 n2
Decimal 20 20 105 n1n2
Function: Specifies the HMI (horizontal motion index) of enlarged
characters.
0
n1
255
0
n2
15
The HMI indicates the horizontal distance between two adjacent
characters, i.e., the width the print head moves after printing one
character.
The HMI is (n1 + n2 x 256)/180”.
The high-order four bits of parameter n2 (bit 7 to bit 4) are ignored. The
HMI can be set to zero.
After specifed command have priority over DC4 DC4 p or DC4 DC4 i.
If the PITCH LOCK option is set to YES in the setup mode, this
command is ignored.
The default setting is “10 cpi x widthwise expansion”.