l
If the counter value set by N5 goes out of the counter operation
range, it will be forced to convert to the minimum by GS c.
With counting down
l
If the counting down reaches the value less than the minimum,
it will be resumed with the maximum.
l
If the counter value set by N5 goes out of the counter operation
range, it will be forced to convert to the maximum by G3 c.
[Default]
N1 = 1, N2 = 65535, N3 = 1, N5 =1
[Reference] GS CO, GS Cl, GS C2, GS c
GS H n
[Name]
Select printing position of HRI characters
[Format]
<1D>H<48>H<n>
[Range]
O
≤
n
≤
3
[Description]
Selects the printing position of HRI characters when printing a bar
code.
l
n
selects the printing position from the following table.
n
Printing position
0
Not printed
1
Above the bar code
2
Below the bar code
3
Both above and below the bar code
l
HRI means Human Readable Interpretation.
[Notes]
l
HRI characters are printed using the font specified by GS f.
[Default]
n = 0
[Reference]
GS f
GS c
[Name]
Print counter
[Format]
<1D>H<63>H
[Description]
Prints the serial counter.
l
Sets the current counter value in the print buffer as a print data
(character string) and then counts up or down the counter based
on the count mode set.
50