Sharp FO-1470 Fax Machine User Manual


 
143
S H A R P
Date Revised: .
Date Issued :Dec. 22, 1998
MATERIAL SAFETY DATA SHEET (1/2)
MSDS No. B-1006
Section 1. Product Identification
Product Code : UX-15CR Imaging Film
S ec ti on 2 . S u ppl ie r' s N a me a nd A dd re ss
Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.
Sect io n 3 . I ng re di en ts
Ingredients CAS No. Proportion OSHA PEL ACGIH TLV Other Limits
Polyethylene terephthalate 25038-59-9 51.0% - - -
Carbon Black 1333-86-4 8.5% 3.5 mg/m
3
3.5 mg/m
3
-
Ethylene-vinyl acetate copolymer 24937-78-8 3.1% - - -
Ester wax 8015-86-9 5.6% - - -
Parraffin Wax 8002-74-2 12.5% - 2 mg/m
3
(fume)
-
Microcrystalline wax 63231-60-7 15.2% - - -
Modified wax 8016-60-2 1.3% - - -
Polyester resin 27923-68-8
1.3% - - -
Others -
1.5% - - -
Section 4. Hazardous Identification (Emergency Overview)
This product is ink film for thermal transfer facsimile. “Ink film” is a thin film coated with ink.
It is no special hazard under normal use condition.
Sect io n 5 .He al th Ha za rd Da ta
Route(s) of Entry : Inhalation? Skin? Ingestion?
Not applicable Not applicable Possible but very unusual
Health Hazards :
The ingredients are not listed in ACGIH(1986) and OSHA(1989) except carbon black and paraffin wax.
Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human carcinogen). This
classification is given to chemicals for which there is inadequate human evidence, but sufficient animal evi-
dence on which to base an opinion of carcinogenicity. The classification is based upon the development of
lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels that induce particle
overload of the lung. Studies performed in animal models other than rats did not show any association
between carbon black and lung tumors.
Signs and Symptoms of Exposure : not applicable
Medical Conditions Generally Aggravated by Exposure : not applicable
Emergency and First Aid Procedures : not applicable
(Country) (Name and Telephone Number)
U.S.A. Sharp Document Network System of America
Telephone number for information: 1-800-237-4277
Emergency telephone number : 1-800-255-3924
Canada Sharp Electronics of Canada Ltd.
Telephone number for information: 905-890-2100
Emergency telephone number : 1-800-424-9300
United
Kingdom
Sharp Electronics (U.K.) Ltd.
Telephone number for information: 01923-474013
all-ux510A.book Page 143 Thursday, September 14, 2000 9:05 AM