Sharp XV-Z20000 Projector User Manual


 
-46
The maintenance indicators (power, lamp and temperature warning indicators) on the projector will let
you be aware of problems inside the projector. If any of the indicators illuminates, follow the relevant
procedures given below.
About the temperature warning indicator
If the temperature inside the
projector increases, due to
blockage of the exhaust or
intake vent, or the setting loca-
tion, “
” will blink in the lower left corner of
the picture. If the temperature keeps on rising,
the lamp will turn off and the temperature warning
indicator will blink, the cooling fan will run, then
the projector will enter the standby mode. After
” appears, be sure to perform the measures
described on the table below.
About the lamp indicator
When the remaining lamp
life becomes 5% or less,
(yellow) and “Change
The Lamp” will be dis-
played on the screen. When the percentage
becomes 0%, it will change to
(red), the lamp
will automatically turn off and then the projector
will automatically enter standby mode. At this
time, the lamp indicator will illuminate in red.
If you try to turn on the projector a fourth time
without replacing the lamp, the projector will
not turn on.
Maintenance indicator Condition
Problem Possible Solution
Temperature
warning
indicator
Normal
Abnormal
Off
Red on
(Standby)
The internal
temperature is
abnormally high.
Abnormal
Blocked exhaust or
intake vent
Relocate the projector to an area
with proper ventilation.
Cooling fan break-
down
Internal circuit failure
Clogged exhaust or
intake vent
Take the projector to your nearest
Sharp Authorized Service Center or
Dealer for repair.
Clean the exhaust and intake vents
according to the procedure on page 47.
Lamp
indicator
Red on
(Standby)
The lamp does
not illuminate.
Burnt-out lamp
Lamp circuit failure
Replace the lamp. (See page 48.)
Take the projector to your nearest
Sharp Authorized Service Center or
Dealer for repair.
Please exercise care when replac-
ing the lamp.
Securely install the lamp unit cover.
Blue on*
Blue
blinks
when the
lamp is
active.
Power
indicator
The power
indicator blinks
in red when the
projector is on.
The lamp unit cover
is open.
Securely install the lamp unit cover.
If the power indicator blinks
even when the lamp unit cover is
securely installed, contact your
nearest Sharp Authorized Service
Center or Dealer for advice.
Blue on*/
Red on
Red blinks
Red blinks
Lamp replace-
ment time.
The remaining lamp
life has become 5%
or less.
* Blue is off when “LED” is set to “Off”. (See page 43.)
Maintenance Indicators/Maintenance
Lamp indicator
Power indicator
Temperature warning indicator