-58
CONTROL CONTENTS COMMAND PARAMETER
RETURN
Power ON
Standby mode
(or 30-second startup time)
RS232C Port Off L N R S _ _ _ 0 OK or ERR ERR
On L N R S _ _ _ 1 OK or ERR ERR
Auto Power Off Off A P O W _ _ _ 0 OK or ERR ERR
On A P O W _ _ _ 1 OK or ERR ERR
Fan Mode Normal H L M D _ _ _ 0 OK or ERR ERR
High H L M D _ _ _ 1 OK or ERR ERR
PRJ Mode Front I M R E _ _ _ 0 OK or ERR ERR
Ceiling + Front I M R E _ _ _ 1 OK or ERR ERR
Rear I M I N _ _ _ 0 OK or ERR ERR
Rear + Front I M I N _ _ _ 1 OK or ERR ERR
All reset A L R E _ _ _ 1 OK or ERR ERR
Language English M E L A _ _ _ 1 OK or ERR ERR
Deutsch M E L A _ _ _ 2 OK or ERR ERR
Español M E L A _ _ _ 3 OK or ERR ERR
Nederlands M E L A _ _ _ 4 OK or ERR ERR
Français M E L A _ _ _ 5 OK or ERR ERR
Italiano M E L A _ _ _ 6 OK or ERR ERR
Svenska M E L A _ _ _ 7 OK or ERR ERR
M E L A _ _ _ 8 OK or ERR ERR
Português M E L A _ _ _ 9 OK or ERR ERR
M E L A _ _ 1 0 OK or ERR ERR
M E L A _ _ 1 1 OK or ERR ERR
Lamp Quantity T L P N _ _ _ 1 “1”
Model Name Check T N A M _ _ _ 1 XV-Z20000/DT-5000
Projector Name Setting P J N 0 _ _ _ 1
Projector Name Setting 1 (First four characters) *
3
P J N 1 * * * * OK or ERR ERR
Projector Name Setting 2 (Middle four characters) *
3
P J N 2 * * * * OK or ERR ERR
Projector Name Setting 3 (Last four characters) *
3
P J N 3 * * * * OK or ERR ERR
Lamp Timer Reset *
4
L P R E _ _ _ 1 ERR OK or ERR
Note
• If an underbar (_) appears in the parameter column, enter a space. If an asterisk (*) appears, enter a value
in the range indicated in brackets under CONTROL CONTENTS.
• Fine Sync can only be set in the displayed RGB mode.
• The return value of “TLTT_ _ _1” becomes “0” when the projector is in the standby mode.
*1
The command parameters for the CLR temperature setting are as follows.
Parameter
5500 _055
6500 _065
7500 _075
8500 _085
9500 _095
10500 _105
*2
The command parameters for the Overscan setting are as follows.
Parameter
10% __10
9% ___9
8% ___8
7% ___7
6% ___6
5% ___5
4% ___4
3% ___3
2% ___2
1% ___1
0% ___0
*3
For setting the projector name, send the commands in order of PJN1, PJN2 and PJN3.
*4
The Lamp Timer Reset command can only be sent in standby mode.