SMC Networks SMC6608M Switch User Manual


 
Statistics
This screen displays statistical information for any port or the
entire switch, depending on the display mode chosen. (See
Item 1 below)
Figure 4-11. Statistics Screen
This screen provides the following options:
1. Highlight “Display” and press <ENTER> to select statistical
display. Use arrow keys to cycle through display selections
(Ports 1-8 or the whole switch). Press <ENTER> to confirm
the choice.
2. Highlight “Refresh Screen” and press <ENTER> to update
all statistics counters.
3. Highlight “Reset Statistics” and press <ENTER> to clear all
statistics counters.
See the chart on the following page for a description of the
statistics displayed on this screen.
4-23
CONFIGURATION AND MANAGEMENT
Statistics
Time Since Last Reset Switch Statistics : 0Day, 2Hr, 5Min, 2Sec
No of Reset Switch Statistics Since Power On: 0
Local Frame Received 0 CRC Errors 0
Forwarded Frames 0 Input Queue Frame Lost 0
Learning Broadcast Frames 0 Output Queue Frame Lost 10
Long Frames 21 No of Frames in Input Queue 0
Short Frames 20 No of Frames in Output Queue 14
Collisions 0 Currently Active Stations 8
Return Refresh Screen Reset Statistics
Selecting one of ports or the switch :
Press <CTRL><X> to cancel. Use cursor keys to do selection.
Press <ENTER> to confirm choice.
Displaying all statistics counters for selected port or whole switch
Switch