Chapter 7 Error Messages
This chapter explains error messages that may be displayed on the Hand-held Monitor.
Powerup Error Messages
If an error occurs during the Hand-held Monitor’s
self-test, this multi-language error display may
appear:
P W R U P E R R O R # 1
E R R E U R # 1
E I G T E S T : F E H L # 1
E R R O R E I N I Z # 1
Cycle power to the Hand-held Monitor and try
again. If the message returns, look for its error
number in the list at right.
#2 The HHM has a faulty EPROM. Obtain a
replacement or an HHM upgrade kit.
#4 The HHM may have been assigned a De-
vice Number already used on the bus. Press
the ON/OFF key, then disconnect the HHM
from the device it is attached to. Press the
ON/OFF key again. Following the instruc-
tions on page 3-4, assign the HHM a differ-
ent Device Number.
At 38.4 Kbaud, unterminated HHM cable
may cause this message. Remove the HHM
cable or check that HHM is connected to a
properly-terminated bus.
This error may occur if the Hand-held Mon-
itor is connected to a bus and an incorrect
baud rate is selected.
#5 This number indicates an internal fault, or
excessive noise on the bus, or that the bus is
operating at a different baud rate from the
HHM. Press the ON/OFF key then discon-
nect the HHM cable from the bus from
the HHM. Press the ON/OFF key again. If
the message reappears, replace the HHM.
This error may occur if the Hand-held Mon-
itor is connected to a bus and an incorrect
baud rate is selected.
#1, 2, 3, or 6 indicates that the Hand-held Monitor