Sony LIB-D81 Personal Computer User Manual


 
48
Appendix
22
Detected SCSI parity error.
Command phase retried but
gave up.
—Yes
23
Detected SCSI parity error.
Data Out phase retried but
gave up.
—Yes
24
Detected a parity error
message. Message In phase
retried but gave up.
—Yes
25
Received Initiator detected
error message. Message
phase retried but gave up.
—Yes
26
Received Initiator detected
error message. Command
phase retried but gave up.
—Yes
27
Received Initiator detected
error message. Status phase
retried but gave up.
—Yes
28
Received Initiator detected
error message. Data In phase
retried but gave up.
—Yes
29
Received Initiator detected
error message. Data Out
phase retried but gave up.
—Yes
2A
Received an illegal message
from the SCSI interface.
—Yes
2B
Received an illegal Identify
message at the SCSI interface
—Yes
2C
Failed reselection. Reselection
retried but gave up.
—Yes
2F
REQ/ACK handshake timeout
or controller chip interruption
timeout at the SCSI interface.
—Yes
30 Reports a unit attention event. Yes
31
An as yet unsupported LUN
specified at the SCSI
interface.
—Yes
32 Loader not yet ready. Yes
33 Loader front door open. Yes
34
Currently in reprogramming
mode.
—Yes
35 Currently in menu mode. Yes
36
Reported an information
exception condition.
—Yes
41
Reception of drive data
timeout at the drive interface.
[L ] and [4 1] appear
alternately on the message
display.
Ye s
42
Received data of abnormal
length from drive at the drive
interface.
[L ] and [4 2] appear
alternately on the message
display.
Ye s
43
Drive detected as offline at the
drive interface.
[L ] and [4 3] appear
alternately on the message
display.
Ye s
70
Detected calibration error
(lower sensor readings
abnormal).
[L ] and [7 0] appear
alternately on the message
display.
Ye s
Error code Description Display Logged