2-27
SRX-T420
REGISTRATION ADJUST
Moves R (red), G (green), and B (blue) in the horizontal and vertical directions by two pixels (maximum)
one pixel at a time so as to adjust registration.
. On: Selects when adjusting.
. Off: Selects when not adjusting.
. H: Pixels move in the horizontal direction.
R: Red pixels horizontally move by two pixels (maximum) one pixel at a time when you click the
[+]/[_] button.
G: Green pixels horizontally move by two pixels (maximum) one pixel at a time when you click the
[+]/[_] button.
B: Blue pixels horizontally move by two pixels (maximum) one pixel at a time when you click the
[+]/[_] button.
. V: Pixels moves in the vertical direction.
R: Red pixels vertically moves by two pixels (maximum) one pixel at a time when you click the
[+]/[_] button.
G: Green pixels vertically moves by two pixels (maximum) one pixel at a time when you click the
[+]/[_] button.
B: Blue pixels vertically moves by two pixels (maximum) one pixel at a time when you click the
[+]/[_] button.
LAMP ADJUST & TIMER RESET
Displays the operation time of a lamp bulb and resets the LAMP TIMER.
. Lamp: Displays the operation time of a lamp bulb.
. [SELECT] button: Clicking the button, displays the LAMP INFORMATION window.
LAMP INFORMATION
. Serial Code: Enter the serial number of a lamp bulb.
. [CHECK] button: Clicking the button with the Serial Code box entered, resets LAMP TIMER.
- Lamp Serial No.: Displays the serial code of a lamp bulb.
- Drive Elec Power (max): Displays maximum driving power.
LAMP ADJUST
. Lamp Axis Adjust Mode
Switches the axis adjust mode of the lamp bulb.
- [START] button: Enables the axis adjustment.
- [STOP] button: Quits the axis adjustment.
. Z Axis Adjust
- Luminance Value: Displays the value of the internal luminance meter.
AIR FILTER TIMER
Displays and resets the operation time of air fi lter.
. Optical: Displays the operation time of the air fi lter on the panel duct.
. [RESET] button: Clicking the button, resets AIR FILTER TIMER.
Fig. 2-7-3b