Sun Microsystems V20Z Server User Manual


 
158 Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide May, 2004
Sensor Set Subcommand
Description: Allows you to set some of the data associated with a specific sensor or
a class of sensors.
Format
Command format:
sensor set [{-i | --id} SENSOR_ID [{-i | --id} SENSOR_ID] …]
{[{-C | --crithigh} VALUE] [[{-c | --critlow} VALUE]
[{-W | --warnhigh] VALUE] [{-w | --warnlow} VALUE] [{-v | --value}
{on|off}] | {-r | --reset}}
sensor set [{-t | --type] TYPE_ID] {[{-C | --crithigh} VALUE]
[[{-c| --critlow} VALUE] [{-W | --warnhigh] VALUE] [{-w | --warnlow}
VALUE] [{-v | --value} {on|off}] | {-r | --reset}}
sensor set [{-R | --resetall}]
TABLE G-4 lists the arguments for this subcommand.
TABLE G-4 Arguments for Subcommand sensor set
Arguments Description
{-i | --id} Specifies the specific sensor on which to operate. You can specify
multiple sensors by repeating --id.
{-t | --type} Specifies the specific sensor class on which to operate (for
example, fan, voltage and so on).
{-C | --crithigh} Specifies the critical high threshold value for the sensor.
Setting the string to clear disables the threshold.
Setting the string to reset sets the value to the original
factory-specified value.
If the value specified ends in a percent sign (%), the threshold
is set to that percentage of the nominal value for the sensor.
Any other value is interpreted as the actual value to which to
set the threshold.
{-c | --critlow} Specifies the critical low threshold value for the sensor. Setting the
string to clear disables the threshold.
{-W | -warnhigh} Specifies the warning high threshold value for the sensor. Setting
the string to clear disables the threshold.
{-w | --warnlow} Specifies the warning low threshold value for the sensor. Setting
the string to clear disables the threshold.