Sun Microsystems V20Z Server User Manual


 
190 Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide May, 2004
76 Check for keyboard errors
7C Set up hardware interrupt vectors
7D Initialize Intelligent System Monitoring
7E Initialize coprocessor if present
80 Disable onboard super I/O ports and IRQs
81 Late POST device initialization
82 Detect and install external RS232 ports
83 Configure non-MCD IDE controllers
84 Detect and install external parallel ports
85 Initialize PC compatible PnP ISA devices
86 Reinitialize onboard I/O ports
87 Configure motherboard configurable devices (optional)
88 Initialize BIOS data area
89 Enable non-maskable interrupts (NMIs)
8A Initialize extended BIOS data area
8B Test and initialize PS/2 mouse
8C Initialize floppy controller
8F Determine number of ATA drives (optional)
90 Initialize hard disk controllers
91 Initialize local bus hard disk controllers
92 Jump to UserPatch2
93 Build MPTABLE for multi processor boards
95 Install CD ROM for boot
96 Clear huge ES segment register
97 Fixup multi processor table
98 Search for option ROMs
99 Check for SMART drive (optional)
9A Shadow option ROMs
9C Set up power management
9D Initialize security engine (optional)
TABLE H-44 BIOS POST Codes
POST Code Description