Sun Microsystems V20Z Server User Manual


 
Chapter 2 IPMI Server Management 33
chaninfo channel Displays information about the selected channel. If no
channel is specified, the command displays information
about the channel currently being used.
EXAMPLES:
ipmitool -I open chaninfo
Channel 0xf info:
Channel Medium Type: System Interface
Channel Protocol Type: KCS
Session Support: session-less
Active Session Count: 0
Protocol Vendor ID: 7154
ipmitool -I open chaninfo 7
Channel 0x7 info:
Channel Medium Type: 802.3 LAN
Channel Protocol Type: IPMB-1.0
Session Support: multi-session
Active Session Count: 1
Protocol Vendor ID: 7154
Alerting: enabled
Per-message Auth: enabled
User Level Auth: enabled
Access Mode: always available
userinfo channel
Note:
Channels 6
and 7 are not
supported on
Sun Fire V20z
servers.
Displays information about configured user information
on a specific LAN channel.
EXAMPLE:
ipmitool -I open userinfo 6
Maximum User IDs : 4
Enabled User IDs : 1
Fixed Name User IDs : 1
Access Available : call-in / callback
Link Authentication : disabled
IPMI Messaging : enabled
chassis status Returns information about the high-level status of the
server chassis and main power subsystem.
identify interval Controls the front panel identification light. The default
value is 15 seconds. Enter “0” to turn it off.
restart_cause Queries the chassis for the cause of the last server restart.
TABLE 2-2 Expressions and Parameters for IPMItool (2 of 4)
Expression Parameter Sub-parameter Description and examples