Telect 007-0001-2600 Network Router User Manual


 
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Poland +1.48.713.239.100 • UK +1.44.1489.889500 • www.telect.com
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 5-2
Item Description Part Number
Front Cover, Blank Covers 17.5-in. space in a 23-in. rack 007-0000-0102
Covers 17.5-in. space in a 19-in. rack 007-0000-0103
Rear Safety Cover Clear heat-resistant wrap 007-0000-0010
Designation Label For vertical array of 18 CB positions 122845
Internal Bus Kits Links BATT input buses of 2 BDFB/BDCBBs
3
007-0002-0010
Links return buses of two BDFB / BDCBBs
3
007-0002-0020
Expander for input battery bus
4
007-0002-0012
Expander
for return bus
4
007-0002-0022
External Return Bus Kits For 12 or 15 in. cable rack
5
:¾ in.c/c holes 007-0000-0115
6
1 in. c/c holes 007-0000-0215
7
1 in. & ¾ in. c/c holes 007-0000-0315
8
For 20 in. cable rack
5
:¾ in. c/c holes 007-0000-0120
9
1 in. c/c holes 007-0000-0220
10
1 in. & ¾ in. c/c holes 007-0000-0320
11
Brackets for 1.5 in.-deep cable rack
12
007-0000-0121
Brackets for a 2 in.-deep cable rack
12
007-0000-0125
Expansion, Common
13
007-0000-0122
Expansion, Insulated
13
007-0000-0123
Lug Fastener Kits For 36, dual-lug load returns
14
007-0000-0225
For 10, dual-lug load returns (spares)
14
007-0000-0231
For 4, dual-lug, input battery or returns
15
007-0000-0230
For 2, internal Input bus expanders
16
007-0000-0232
Relay Racks, 7-ft Seismic EIA with unequal flanges, white 723-0707-2130-001
WECO with unequal flanges, white 723-0701-2130-001
End Panel, white 071-3000-0002
Enclosed Cabinet Standard Zone 4 for up to 4 BDFB / BDCBBs contact Telect
1. Contact Telect for alternate circuit breakers, such as mid-trip or short delay. SEE CAUTION THAT FOLLOWS.
2. The adapter bridges adjacent single-pole CB slots for use with double-pole breakers.
3. Each expansion kit contains parts and fasteners to link adjacent (above/below) BDFB / BDCBBs in a rack. Three
kits are required to link a maximum of four, 10RU BDFB / BDCBBs per rack.
4. Bracket and fasteners used to expand from four 750/777.7MCM input positions to six to accommodate up to four
multiple 600A BDFB / BDCBBs in a 2400A rack.
5. Each kit contains parts and fasteners to install an overhead return bus to the plant’s 12 in,-, 15 in.-, or 20 in.-wide
ladder rack system. Each copper plate handles multiple dual-lug connections for a total 600A continuous load at
800A max. load. External return buses accommodate dual lugs with ¾ in. and/or 1 in. center-to-center (c/c) hole
spacings. Brackets for 1.5 in.- versus 2.0 in.-deep cable racks are ordered separately.
6. 32 sets of dual holes. Lugs can be bolted to both sides for a total of 64 lug connections.
7. 16 sets of dual holes. Lugs can be bolted to both sides for a total of 32 lug connections.
8. 12 sets of dual holes with 1 in. center spacing; 22 sets of dual holes with ¾ in. center spacing. (Not all hole sets
can be used when accommodating both types of lugs.) Lugs can be bolted to both sides.
9. 38 sets of dual holes. Lugs can be bolted to both sides for a total of 76 lug connections.