Texas Instruments TNETX3270 Switch User Manual


 
TNETX3270
ThunderSWITCH 24/3 ETHERNET SWITCH
WITH 24 10-MBIT/S PORTS AND 3 10-/100-MBIT/S PORTS
SPWS043B – NOVEMBER 1997 – REVISED APRIL 1999
53
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
10-Mbit/s interface (ports 00–23)
timing requirements (see Notes 3 through 6 and Figure 13)
NO. MIN MAX UNIT
1 t
c(THxCLK)
Cycle time, THxCLK 50 58 ns
2 T
w(THxCLK)
Pulse duration, THxCLK high or low 23 27 ns
3 t
su(THxSYNC)
Setup time, THxSYNC high before THxCLK 8 ns
4 t
su(THxCOL)
Setup time, THxCOL high before THxCLK 8 ns
4 t
su(THxCRS)
Setup time, THxCRS high before THxCLK 8 ns
4 t
su(THxLINK)
Setup time, THxLINK high before THxCLK 8 ns
4 t
su(THxRXD)
Setup time, THxRXD3–THxRXD0 valid before THxCLK 8 ns
4 t
su(THxRXDV)
Setup time, THxRXDV high before THxCLK 8 ns
5 t
h(THxSYNC)
Hold time, THxSYNC high after THxCLK 8 ns
6 t
h(THxCOL)
Hold time, THxCOL high after THxCLK 8 ns
6 t
h(THxCRS)
Hold time, THxCRS high after THxCLK 8 ns
6 t
h(THxLINK)
Hold time, THxLINK high after THxCLK 8 ns
6 t
h(THxRXD)
Hold time, THxRXD3–THxRXD0 valid after THxCLK 8 ns
6 t
h(THxRXV)
Hold time, THxRXDV high after THxCLK 8 ns
t
r(THxCLK)
Rise time, THxCLK 2 ns
t
f(THxCLK)
Fall time, THxCLK 2 ns
THx = TH0, TH1, and TH2
NOTES: 3. The TNETE2008 must supply at least two THxSYNC pulses under normal conditions before driving valid data on the inputs to the
TNETX3270, or before expecting valid data on the outputs from the TNETX3270. This means that at least two full sequences must
be executed; only with the third THxSYNC pulse is valid data presented/expected.
4. At least two clocks must be driven before the deassertion of the system reset signal, and a minimum of two clocks must be driven
after the deassertion of the the system reset signal to ensure complete initialization of the internal circuitry of the TNETX3270 before
there is any valid activity across the interface.
5. For receive data, the TNETE2008 asserts the THxCOL signal during the appropriate slot time if it was asserted for any of the four
bits of data corresponding to that slot time.
6. For receive data, the TNETE2008 asserts the THxRXDV signal only if there are four valid bits of data in the nibble.
operating characteristics over recommended operating conditions (see Notes 3 through 6 and
Figure 13)
NO. PARAMETER MIN MAX UNIT
7 t
d(THxEN)
Delay time, from THxCLKto THxTXEN 13.5 ns
7 t
d(THxTXD)
Delay time, from THxCLKto THxTXD3–THxTXD0 valid 13.5 ns
7 t
d(THxRENEG)
Delay time, from THxCLKto THxRENEG 13.5 ns
8 t
d(THxTXEN)
Delay time, from THxCLK to THxTXEN 0 ns
8 t
d(THxTXD)
Delay time, from THxCLK to THxTXD3–THxTXD0 invalid 0 ns
8 t
d(THxRENEG)
Delay time, from THxCLK to THxRENEG 0 ns
THx = TH0, TH1, and TH2
NOTES: 3. The TNETE2008 must supply at least two THxSYNC pulses under normal conditions before driving valid data on the inputs to the
TNETX3270, or before expecting valid data on the outputs from the TNETX3270. This means that at least two full sequences must
be executed; only with the third THxSYNC pulse is valid data presented/expected.
4. At least two clocks must be driven before the deassertion of the system reset signal, and a minimum of two clocks must be driven
after the deassertion of the the system reset signal to ensure complete initialization of the internal circuitry of the TNETX3270 before
there is any valid activity across the interface.
5. For receive data, TNETE2008 asserts the THxCOL signal during the appropriate slot time if it was asserted for any of the four bits
of data corresponding to that slot time.
6. For receive data, the TNETE2008 asserts the THxRXDV signal only if there are four valid bits of data in the nibble.