Toshiba 281C All in One Printer User Manual


 
e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE© June 2005 TOSHIBA TEC
2 - 124
569Image
control
Image quality closed-loop
control automatic start-up/
Temperature setting of
fuser roller at power-ON
ALL
(color)
8
<0-20>
MSets the fuser roller
temperature to perform
closed-loop control
when 1! or 2! (valid) is
set in 08-559.
0:20°C1: 25°C
2:30°C3: 35°C
4:40°C5: 45°C
6:50°C7: 55°C
8:60°C9: 65°C
10: 70°C11: 75°C
12: 80°C13: 85°C
14: 90°C15: 95°C
16: 10C17: 105°C
18: 110°C19: 115°C
20: 120°C
1
570Image
control
Image quality closed-loop
control automatic start-up/
Relative humidity differ-
ence setting
ALL
(color)
4
<0-6>
MSets the relative humid-
ity difference to per-
form the closed-loop
control when 1! or 2!
(valid) is set in 08-565.
0: 0% 1: 5%
2: 10% 3: 15%
4: 20%5: 25%
6: 30%
1
571Image
control
Image quality closed-loop
control automatic start-up/
Setting of period of time
unattended
ALL
(color)
4
<0-24>
MSets the period of time
unattended to perform
closed-loop control
when 1! or 2! (valid) is
set in 08-566.
Setting value x 1 (hour)
1
572Image
control
Image quality closed-loop
control automatic start-up/
Setting of accumulated
print volume
ALL
(color)
10
<0-30>
MSets the number of
accumulated print vol-
ume to perform closed-
loop control when 1! or
2! (valid) is set in 08-
567.
Setting value x 100
(pages)
1
573Image
control
Abnormality detection
count (Y)
Display/0 clearing
ALL0
<0-16>
MCounts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
574Image
control
Abnormality detection
count (M)
Display/0 clearing
ALL0
<0-16>
MCounts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
575Image
control
Abnormality detection
count (C)
Display/0 clearing
ALL0
<0-16>
MCounts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
576Image
control
Abnormality detection
count (K)
Display/0 clearing
ALL0
<0-16>
MCounts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAMContents
Pro-
cedur
e