e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE© June 2005 TOSHIBA TEC
2 - 142
868Develop-
ment
Color auto-toner adjust-
ment finishing range set-
ting
ALL
(color)
4
<0-255>
MSets the difference from
the target value for
judging whether the
color auto-toner adjust-
ment finishes correctly
or not.
1
869Develop-
ment
Color auto-toner control
environment and life light
amount correction/correc-
tion finishing range setting
ALL
(color)
5
<0-255>
MSets the difference from
the target value for
judging whether the
light amount correction
finishes correctly or not.
1
870Develop-
ment
Color auto-toner sensor/
setting of number of times
of error detection at light
amount correction
ALL
(color)
3
<0-255>
MSets the number of
times of continuous
error detection before
the light amount correc-
tion abnormality is dis-
played.
1
871Develop-
ment
Color auto-toner control
environment and life light
amount correction/display
of number of times of refer-
ence plate detection error
ALL
(color)
0
<0-255>
MDisplays the number of
times of the reference
plate detection error for
the environment and life
light amount correction.
2
872Develop-
ment
Color auto-toner control
environment and life light
amount correction/display
of number of times of light
amount control voltage
adjustment error
ALL
(color)
0
<0-255>
MDisplays the number of
times of the light
amount control voltage
adjustment error for the
environment and life
light amount correction.
2
873-0Develop-
ment
Color auto-
toner control/
developer ini-
tial output set-
ting
YALL
(color)
256
<0-1023>
MSets the initial devel-
oper output target
value.
4
873-1Develop-
ment
MALL
(color)
256
<0-1023>
M4
873-2Develop-
ment
CALL
(color)
256
<0-1023>
M4
874Develop-
ment
Color developer life correc-
tion
ALL
(color)
0
<0-1>
MSets whether the toner
density detection volt-
age correction is per-
formed or not
depending on the
developer life in the
color auto-toner control.
0: Corrected
1: Not corrected
1
875-0Develop-
ment
Color devel-
oper life cor-
rection value
(segment 0)
YALL
(color)
0
<-512-
511>
MSets the correction
amount of the toner
density detection volt-
age depending on the
developer life. In this
code, the life count
within 0-2000 is set as
the correction amount.
4
875-1MALL
(color)
0
<-512-
511>
M4
875-2CALL
(color)
0
<-512-
511>
M4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAMContents
Pro-
cedur
e