Toshiba 281C All in One Printer User Manual


 
© June 2005 TOSHIBA TECe-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 47
2
305ScannerImage location adjustment
of secondary scanning
direction
(scanner section)
ALL124
<92-164>
SYSWhen the value
increases by 1!, the
image shifts by approx.
0.137 mm toward the
trailing edge of the
paper.
1
306ScannerImage location adjustment
of secondary scanning
direction
(scanner section)
ALL113
<0-255>
SYSWhen the value
increases by 1!, the
image shifts by approx.
0.0423 mm toward the
front side of the paper.
1
308ScannerDistortion modeALL--Moves carriages to the
adjusting position.
(Chap. 3.4.4)
6
330-0Image
control
Image quality
closed-loop
control con-
trast voltage
correction/
Mode 2 maxi-
mum number
of time cor-
rected
YALL3
<0-255>
MSets the maximum cor-
rection number of time
of the contrast voltage
in the closed-loop con-
trol mode 2.
4
330-1MALL3
<0-255>
M4
330-2CALL3
<0-255>
M4
330-3KALL3
<0-255>
M4
331-0Image
control
Image quality
closed-loop
control laser
power correc-
tion/Mode 2
maximum
number of
time corrected
YALL2
<0-255>
MSets the maximum cor-
rection number of time
of the laser power in the
closed-loop control
mode 2.
4
331-1MALL2
<0-255>
M4
331-2CALL2
<0-255>
M4
331-3KALL2
<0-255>
M4
332-0Image
control
Image quality
closed-loop
control con-
trast voltage
correction/
Mode 1 maxi-
mum number
of time cor-
rected
YALL1
<0-255>
MSets the maximum cor-
rection number of time
of the contrast voltage
in the closed-loop con-
trol mode 1.
4
332-1MALL1
<0-255>
M4
332-2CALL1
<0-255>
M4
332-3KALL1
<0-255>
M4
333-0Image
control
Image quality
closed-loop
control laser
power correc-
tion/Mode 1
maximum
number of
time corrected
YALL1
<0-255>
MSets the maximum cor-
rection number of time
of the laser power in the
closed-loop control
mode 1.
4
333-1MALL1
<0-255>
M4
333-2CALL1
<0-255>
M4
333-3KALL1
<0-255>
M4
334Image
control
Main charger grid calibra-
tion voltage 1 (low)
ALL300
<210-
390>
MTransformer output cali-
bration of the main
charger grid bias. When
replacing the high-volt-
age transformer, the
values listed in attached
data sheet are entered.
(Unit: V)
1
335Image
control
Main charger grid calibra-
tion voltage 2 (high)
ALL1000
<900-
1100>
M1
Adjustment mode (05)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAMContents
Pro-
cedur
e