© June 2005 TOSHIBA TECe-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 89
2
Notes:
1.The digit after the hyphen in Code! of the following table is a sub code.
2.In RAM!, the NVRAM of the board in which the data of each code is stored is indicated. M!
stands for the LGC board, SYS!, NIC! and UTY! stands for the SYS board.
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAMContents
Pro-
cedur
e
200GeneralDate and time settingALL-
<13 dig-
its>
-Year/month/date/day/
hour/minute/second
Example:
03 07 0 13 13 27 48
Day! - 0! is for Sun-
day!. Proceeds Monday
through Saturday from
1! to 6!.
5
201GeneralDestination selectionALLEUR: 0
UC: 1
JPN: 2
<0-3>
M0: EUR
1: UC
2: JPN
3: Other
1
202User
interface
Counter installed externallyALL0
<0-4>
M0: No external counter
1: Coin controller
2: Copy key card
3: Key copy counter
4: Key card for OEM1
1
203GeneralLine adjustment modeALL0
<0-1>
M0: For factory ship-
ment
1: For line
*Field: 0! must be
selected
1
204User
interface
Auto-clear timer settingALL3
<0-10>
SYSTimer to return the
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10:
Set number x 15
sec.
1
205User
interface
Auto power save mode
timer setting
ALL11
<0, 6-15>
SYSTimer to automatically
switch to the energy
saving mode when the
equipment has not
been used
0: Invalid 6: 3min.
7: 4min. 8: 5min.
9: 7min.
10:10min.
11: 15min.
12: 20min.
13: 30min.
14: 45min.
15: 60min.
1