Toshiba 386SX Computer Hardware User Manual


 
AR-B1375/AR-B1376 User s Guide
5-8
NOTE: 1. If you program the watchdog to generate IRQ15 signal when it times out, you should initial IRQ15
interrupt vector and enable the second interrupt controller (8259 PIC) in order to enable CPU to process
this interrupt. An interrupt service routine is required too.
2. Before you initial the interrupt vector of IRQ15 and enable the PIC, please enable the watchdog timer
previously, otherwise the watchdog timer will generate an interrupt at the time watchdog timer is enabled.
5.4.2 Watchdog Timer Enabled
To enable the watchdog timer, you have to output a byte of timer factor to the watchdog register whose address is
214H or Base Port. The following is a BASICA program, which demonstrates how to enable the watchdog timer
and set the time-out period at 24 seconds.
1000 REM Points to command register
1010 WD_REG% = 214H
1020 REM Timer factor = 84H (or 0C4H)
1030 TIMER_FACTOR% = %H84
1040 REM Output factor to watchdog register
1050 OUT WD_REG%, TIMER_FACTOR%
.,etc.
5.4.3 Watchdog Timer Trigger
After you enable the watchdog timer, your program must write the same factor as enabling to the watchdog register
at least once every time-out period to its previous setting. You can change the time-out period by writing another
timer factor to the watchdog register at any time, and you must trigger the watchdog before the new time-out period
in next trigger. Below is a BASICA program which demonstrates how to trigger the watchdog timer:
2000 REM Points to command register
2010 WD_REG% = 214H
2020 REM Timer factor = 84H (or 0C4H)
2030 TIMER_FACTOR% = &H84
2040 REM Output factor to watchdog register
2050 OUT WD_REG%, TIMER_FACTOR%
.,etc.
5.4.4 Watchdog Timer Disabled
To disable the watchdog timer, simply write a 00H to the watchdog register.
3000 REM Points to command register
3010 WD_REG% = BASE_PORT%
3020 REM Timer factor = 0
3030 TIMER_FACTOR% = 0
3040 REM Output factor to watchdog register
3050 OUT WD_REG%, TIMER_FACTOR%
., etc.