Toshiba FS-1650 Cash Register User Manual


 
– 46 –
EO1-11113
Address No. Description of Programming Contents
--
Continued
--
8 Whole Package Quantity (for Split Package Pricing PLUs)
[#]
Enter the whole package quantity in max. 2 digits (1 to 99), or enter 0 to
cancel the Split Package Pricing status.
NOTES: This setting is not allowed for PLUs with the Scale-compulsory status.
When the option “Preset Point for one decimal digit” is selected, this
setting is not allowed to any PLUs.
9 PLU Group No. (for purposes of reports)
Enter a 2-digit code (1 to 99) as a PLU Group No. to which the PLU
belongs, and depress [#]. To cancel the Group No. once set, enter 0 and
depress [#].
11 Tare Table No. (for Scale-compulsory PLUs only)
Enter the Tare Table No. (1 to 9). The content of each Tare Table is set later
in a separate operation (Submode 26). In a scale item entry of a PLU with a
Tare Table No. set, the tare weight preset in the Tare Table will automatically
be subtracted from the total weight read from the scale. Enter 0 to cancel a
Tare Table No. once set. Or skip this address setting for PLUs not needing
any tare weight calculations.
12 Individual PLU Unit Weight Table Code (for Scale-compulsory PLUs only)
LB unit Kg unit
0: General Unit Weight (set in Submode 26)
1: 1 LB 1 Kg
2: 2 LB 2 Kg
3: 3 LB 3 Kg
4: 4 LB 4 Kg
5: 5 LB 5 Kg
6: 6 LB 6 Kg
7: 7 LB 7 Kg
8: 8 LB 8 Kg
9: 9 LB 9 Kg
10: 1/2 LB 100 Kg
11: 1/4 LB not applicable
NOTE: Whether the ECR adopts the LB or Kg unit system is determined by a
program option selection.
[#]
[#]
ADDITIONAL NOTES
If a PLU is linked to an Other Income Department, the PLU is automatically set as Other Income
PLU.
Amount Limits (High Amount, Low Amount) of each open-price PLU will be determined by those of
its link department.